Return To Restaurant Listing | Return to Environmental Health Homepage

Facility: Pizza Factory Amorim Enterprises Inc
Address: 447 5th St., Gustine, CA

The most recent inspection of this food facility resulted in a rating of
Good (Total Points: 4.00)
0-6  Points: Good
7-13 Points: Satisfactory
14+  Points: Unsatisfactory
Rating on date 5-14-2019: Good (Total Points: 4.00)
DateViolationPointsCorrectionInspector CommentsFacility Area
5-14-2019 The walls / ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114065, 114067, 114069, 114175, 114143, 114257, 114259.2, 114266, 114268, 114268.1, 114271, 114272) 2.00 All food facilities shall be kept clean, fully operative, and in good repair. Floor surfaces in all areas in which food is prepared, packaged or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and in all restrooms and hand washing areas shall be smooth and of durable construction and made from non absorbent material that is easily cleanable.

Each permanent food facility shall be fully enclosed in a building consisting of permanent floors, walls, and an overhead structure that meets minimum standards. Food facilities that are not fully enclosed on all sides and that are in operation on January 1, 1985, shall not be required to meet the requirements of this section until the facility is remodeled or has a significant menu change or a change in its method of operation. Full enclosure is not required for dining areas and certain other areas when approved for outdoor food services.
Observed overall improvement in the reduced number of significantly cracked / damaged flooring tiles near the register area. Continue to work on replacing the remaining cracked / broken tiles near the register area, especially any remaining tiles where pieces are missing.

Floor surfaces in all areas in which food is prepared, packaged or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and in all restrooms and hand washing areas shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius and shall extend up the wall at least 4 inches.
0102 FOOD ESTAB. W/FOOD PREP 50-149 SEATS
5-14-2019 The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269) 2.00 All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Observed one of the threaded hosebibb type faucets (hot water side) at the janitorial sink location lacks a backflow protection device. The potable water supply shall be protected at all times from potential backflow. Approved backflow prevention / anti siphon devices shall be installed on the discharge side of all hose bibs. Provide the required protective device on threaded hosebibbs in this facility location. 0102 FOOD ESTAB. W/FOOD PREP 50-149 SEATS


Rating on date 3-28-2018: Satisfactory (Total Points: 8.00)
DateViolationPointsCorrectionInspector CommentsFacility Area
3-28-2018 The walls / ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114065, 114067, 114069, 114175, 114143, 114257, 114259.2, 114266, 114268, 114268.1, 114271, 114272) 2.00 All food facilities shall be kept clean, fully operative, and in good repair. Floor surfaces in all areas in which food is prepared, packaged or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and in all restrooms and hand washing areas shall be smooth and of durable construction and made from non absorbent material that is easily cleanable.

Each permanent food facility shall be fully enclosed in a building consisting of permanent floors, walls, and an overhead structure that meets minimum standards. Food facilities that are not fully enclosed on all sides and that are in operation on January 1, 1985, shall not be required to meet the requirements of this section until the facility is remodeled or has a significant menu change or a change in its method of operation. Full enclosure is not required for dining areas and certain other areas when approved for outdoor food services.
Observed small number of cracked / damaged flooring tiles near the register area. Repair / replace broken tiles.

Floor surfaces in all areas in which food is prepared, packaged or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and in all restrooms and hand washing areas shall be coved at the juncture of the floor and wall with a 3/8 inch minimum radius and shall extend up the wall at least 4 inches.
0102 FOOD ESTAB. W/FOOD PREP 50-149 SEATS
3-28-2018 All food employees shall have adequate knowledge of and be trained in food safety as it relates to their assigned duties. The person in charge shall have adequate knowledge of, and shall educate employees of the food facility regarding major food allergens. (113947) Food facilities that prepare, handle or serve non-prepackaged potentially hazardous food, shall have an employee who has passed an approved food safety certification examination. (113947-113947.1) 2.00 The responsibilities of the staff member certified in food safety include ensuring that all employees who handle, or have responsibility for handling, unpackaged foods of any kind have sufficient knowledge to ensure the safe preparation and /or service of the food. The nature and extent of the knowledge that each employee is required to have may be tailored, as appropriate, to the employee's duties related to food safety issues. (1) Observed lack of knowledge of the location of current food handler card copies. Obtain and keep unexpired copies of food handler cards for staff at the facility location; ensure any new hires obtain / provide a copy of their food handler card within 30 days of their hire date. Each food facility that employs a food handler shall maintain records documenting that each food handler employed has a valid food handler card, and shall provide those records to the local enforcement officer upon request.

(2) Observed lack of knowledge of the correct testing procedures (method and frequency) to ensure sanitizer in use at the facility is at the correct strength. Re-train staff as to the proper strength, use, and testing frequency of all sanitizer solutions. Ensure test strips that match the sanitizer in use (both at the three compartment sink and in the rag buckets) are present in the facility at all times, and are being correctly paired and used on a daily basis:
chlorine = 100 ppm solution for not less than 30 seconds of contact time
quat ammonia = 200 ppm solution for not less than 60 seconds of contact time

Employees improperly trained.
0102 FOOD ESTAB. W/FOOD PREP 50-149 SEATS
3-28-2018 Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and materials shall be provided to measure the applicable sanitization method. (114067(f,g), 114099, 114099.1, 114099.2, 114099.3, 114099.4, 114099.5, 114099.6, 114099.7, 114101, 114101.1, 114101.2, 114103, 114107, 114125) 2.00 Provide a sink with at least 3 compartments with 2 integral metal drainboards. The sink compartments and drainage facilities shall be large enough to accommodate the largest utensil or piece of equipment to be cleaned therein.

Clean the utensils in one of the following ways:

(1) Manual warewashing shall be accomplished by using a 3-compartment sink where the utensils are first pre-cleaned, then washed, rinsed, sanitized, and air dried. The temperature of the washing solution shall be maintained at not less than 100°F or the temperature specified on the cleaning agent manufacturer's label instructions. The utensils shall then be rinsed in clear water before being immersed in a sanitizing solution. Manual sanitization shall be accomplished in the final sanitizing rinse by one of the following:
(a) Immersion for at least 30 seconds where the water temperature is maintained at 171°F or above.
(b) The application of sanitizing chemicals by immersion, manual swabbing, or brushing, using one of the following solutions:
(1) Contact with a solution of 100 ppm available chlorine solution for at least 30 seconds.
(2) Contact with a solution of 25 ppm available iodine for at least one minute.
(3) Contact with a solution of 200 ppm quaternary ammonium for at least one minute.
(4) Contact with a solution of ozone that meets the requirements of Section 180.940 of Title 40 of the Code of Federal Regulations and that is generated by a device located onsite at the food facility that meets all of the requirements of 114099.6.
(c) Other methods approved by the enforcement agency.

(2) Mechanical machine warewashing shall be accomplished by using an approved machine installed and operated in accordance with the manufacturer's specifications. Soiled items to be cleaned in a warewashing machine shall be loaded in racks, trays, or baskets or onto conveyors in a position that exposes the items to the unobstructed spray during all cycles and allows the items to drain. Mechanical sanitization shall be accomplished in the final sanitizing rinse by one of the following:
(a) By being cycled through equipment achieving a utensil surface temperature of 160°F or above.
(b) The mechanical application of sanitizing chemicals by pressure spraying methods using one of the following:
(1) Contact with a solution of 50 ppm available chlorine solution for at least 30 seconds.
(2) Contact with a solution of 25 ppm available iodine for at least one minute.
(3) Contact with any chemical sanitizer that meets the requirements of Section 180.940 of Title 40 of the Code of Federal Regulations when used in accordance with both the sanitizer manufacturers use directions and the machine manufacturer's specifications.

Provide testing equipment and materials to adequately measure the applicable sanitization method.
Observed lack of knowledge of the location of the test strips needed to measure the applicable manual sanitizer concentration. Obtain and use matching test strips to verify sanitizer is of sufficient strength to act as an appropriate manual sanitizing agent (100 ppm for chlorine, 200 ppm for quat ammonia). 0102 FOOD ESTAB. W/FOOD PREP 50-149 SEATS
3-28-2018 The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269) 2.00 All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Observed pipe below the front area handwashing sink is leaking / dripping into a bucket. Properly repair the dripping pipe. 0102 FOOD ESTAB. W/FOOD PREP 50-149 SEATS