7-02-2021 |
All utensils and equipment shall be fully operative, clean, and in good repair. (114115, 114175). All utensils and equipment shall be approved, installed properly, and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, 114130.6, 114132, 114133, 114137, 114139, 114143, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114175, 114177, 114180, 114182)
| 2.00 |
Equipment food-contact surfaces and utensils shall be clean to sight and touch. The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other debris accumulations.
Keep all food facilities, and all utensils, display cases, windows, counters, shelves, tables, refrigeration units, sinks, dishwashing machines, and other equipment or utensils used in the storage, preparation, sale, service, and display of food, clean, fully operative, and in good repair.
The non-food-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris. Equipment shall be reassembled so that food-contact surfaces are not contaminated.
|
1) WALK-IN FREEZER: Loud noises were coming from the compressor fan above (outside) the unit. Repair.
2) WALK-IN REFRIGERATOR: White sauce accumulation near the door hinge of the proofer. Clean.
3) WALK-IN REFRIGERATOR: Repeat violation. Dark mold accumulation on the underside of some shelving units. Clean.
4) WALK-IN REFRIGERATOR: Replace all deteriorated plastic sheets near the door. Some were missing parts. Some were taped together.
5) FRONT HANDWASHING SINK AREA: Repair the cabinet door that had a missing nut to hold the screw.
|
0101 FOOD ESTAB. W/FOOD PREP 0-49 SEATS (HM4)
|
7-02-2021 |
Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons: in establishments with more than 20,000 sq ft.; establishments offering on-site food consumption. (113953, 113953.1, 113953.2, 114250, 114250.1, 114276)
| 1.00 |
Provide clean toilet facilities in good repair. Provide permanently installed toilet tissue dispenser(s) in all toilet facilities. Provide handwashing facilities within or adjacent to all toilet facilities. Soap shall be provided in dispensers at, or adjacent to, handwashing facilities. Single-use sanitary towels in dispensers or hot-air blowers shall be provided at handwashing facilities.
Customer restrooms are required for food facilities of more than 20,000 square feet if they were constructed after July 1 1984, and also applies to facilities of any size that were constructed after January 1, 2004 where there is onsite consumption of food. A "take-out only" food facility, with no seating indoors or outdoors, may not be required to provide customer restrooms. Check with the Division of Environmental Health and with the appropriate Planning Department before removing or restricting access to customer restrooms.
|
1) RESTROOM NEAR THE ELECTRICAL PANEL COVER: Repair the non-functional ceiling ventilation fan.
2) RESTROOM NEAR THE ELECTRICAL PANEL COVER: Dust accumulation on the white ventilation cover in the ceiling. Clean.
3) RESTROOM NEAR THE ELECTRICAL PANEL COVER: Adjust the self-closer hinges on the door so the door can self-close.
4) RESTROOM ACROSS THE ELECTRICAL PANEL COVER: Dust accumulation on the white ventilation cover in the ceiling. Clean.
|
0101 FOOD ESTAB. W/FOOD PREP 0-49 SEATS (HM4)
|
7-02-2021 |
The walls / ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114065, 114067, 114069, 114175, 114143, 114257, 114259.2, 114266, 114268, 114268.1, 114271, 114272)
| 2.00 |
All food facilities shall be kept clean, fully operative, and in good repair. Floor surfaces in all areas in which food is prepared, packaged or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and in all restrooms and hand washing areas shall be smooth and of durable construction and made from non absorbent material that is easily cleanable.
Each permanent food facility shall be fully enclosed in a building consisting of permanent floors, walls, and an overhead structure that meets minimum standards. Food facilities that are not fully enclosed on all sides and that are in operation on January 1, 1985, shall not be required to meet the requirements of this section until the facility is remodeled or has a significant menu change or a change in its method of operation. Full enclosure is not required for dining areas and certain other areas when approved for outdoor food services.
|
1) SODA MACHINE AREA: Repeat violation. Debris accumulation on the floor. Clean.
2) MOP SINK AREA: Repair the wall corners near the mop sink. The wall material (FRP) was pulled off.
3) CEILING ABOVE THE WALK-IN REFRIGERATOR: Replace the (2) ceiling panels with brown stains.
|
0101 FOOD ESTAB. W/FOOD PREP 0-49 SEATS (HM4)
|
7-02-2021 |
Handwashing signs shall be posted in each toilet room, directing attention to the need to thoroughly wash hands after using the restroom. (113953.5)
No smoking signs shall be posted in food preparation, food storage, and warewashing areas. (113978)
Consumers shall be notified that clean tableware is to be used when they return to self-service areas such as salad bars and buffets. (114075)
Any food facility constructed before January 1, 2004 without public toilet facilities shall prominently post a sign within the food facility in a public area stating that toilet facilities are not provided. (113725.1, 114276, 114381 (e))
| 2.00 |
Post permit in a conspicuous place (It is recommended that the permit be in customer view.). Post a notice advising patrons that a copy of the most recent routine inspection report is available for review by interested parties. Keep a copy of the most recent health inspection report at the facility for customer review purposes.
Post and maintain a legible and conspicuous sign in each toilet room directing attention to the need to thoroughly wash hands after using the toilet.
Post and maintain a legible "No Smoking" sign in food preparation, food storage, and utensil washing areas.
|
RESTROOM NEAR THE ELECTRICAL PANEL: Repeat violation. Provide a handwashing sign near the handwashing sink.
|
0101 FOOD ESTAB. W/FOOD PREP 0-49 SEATS (HM4)
|
7-02-2021 |
The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269)
| 1.00 |
All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair.
|
MOP SINK: Repair/replace the leaking center vacuum breaker (bell) on the faucet fixture.
|
0101 FOOD ESTAB. W/FOOD PREP 0-49 SEATS (HM4)
|