Return To Restaurant Listing | Return to Environmental Health Homepage

Facility: Chevron #2
Address: 32923 Sullivan Road, Gustine, CA

The most recent inspection of this food facility resulted in a rating of
Good (Total Points: 4.00)
0-6  Points: Good
7-13 Points: Satisfactory
14+  Points: Unsatisfactory
Rating on date 10-22-2019: Good (Total Points: 4.00)
DateViolationPointsCorrectionInspector CommentsFacility Area
10-22-2019 Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors, and smoke and be approved by the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) 2.00 All areas shall have sufficient ventilation to facilitate proper food storage and to provide a reasonable condition of comfort for each employee, consistent with the job performed by the employee.

Light fixtures in areas where food is prepared, open food is stored, or utensils are cleaned shall be of shatterproof construction or shall be protected with shatterproof shields and shall be readily cleanable. In every room and area in which any food is prepared, manufactured, processed, or prepackaged, or in which equipment or utensils are cleaned, sufficient natural or artificial lighting shall be provided to produce the following light intensity, while the area is in use:
(a) At least 10-foot candles for the following:
(1) At a distance of 30 inches above the floor, in walk-in refrigeration units, and dry food storage areas.
(2) At a working surface on which alcoholic beverages are prepared or where utensils used in the preparation or service of alcoholic beverages are cleaned.
(3) Inside equipment, such as reach-in or under-the-counter refrigerators.
(b) At least 20-foot candles for the following:
(1) At a surface where food is provided for consumer self-service or where fresh produce or prepackaged foods are sold or offered for consumption.
(2) In server stations where food is prepared.
(3) At a distance of 30 inches above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms.
(c) Except in server stations where food is prepared, at least 50-foot candles at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
Observed the fan units in both restrooms are not functioning. Repair/replace units so adequate air circulation is provide inside the restrooms. Toilet rooms shall be vented to the outside air by means of an openable, screened window, an air shaft, or a light-switch-activated exhaust fan, consistent with the requirements of local building codes. 0110 RETAIL MARKET<2000 SQ FT (HM3)
10-22-2019 The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269) 0.00 All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Observed that the three compartment sink does not drain to the floor drain under the janitorial sink. Not sure if this was grandfathered in. Will look into further and if correction s need to be made will inform facility.

Observed the build up of dead crickets inside the floor drain in the back area under the janitorial sink. Clean and increase frequency to prevent build up.
0110 RETAIL MARKET<2000 SQ FT (HM3)
10-22-2019 The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269) 2.00 All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Observed Black Widow spider and eggs at the well head area. Increase maintenance and cleaning of the well head area to keep it clear from debris and vermin.

Observed well head is slightly rusted and may need to have parts replaced due to rust and water damage.
0151 CALCODE WELL WATER ANALYSES REQUIRED


Rating on date 9-05-2018: Satisfactory (Total Points: 10.00)
DateViolationPointsCorrectionInspector CommentsFacility Area
9-05-2018 The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269) 0.00 All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Observed the lack of two back flow hose bibs on the threaded faucets to the left of the entrance door and at the back of the facility. Provide back flow hose bibs on all connections that have a threaded port/connection.

Note: Recommend preventative replacement of parts near the minor leak at the well head. The area starting to develop rust and debris build up.
0151 CALCODE WELL WATER ANALYSES REQUIRED
9-05-2018 Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors, and smoke and be approved by the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) 2.00 All areas shall have sufficient ventilation to facilitate proper food storage and to provide a reasonable condition of comfort for each employee, consistent with the job performed by the employee.

Light fixtures in areas where food is prepared, open food is stored, or utensils are cleaned shall be of shatterproof construction or shall be protected with shatterproof shields and shall be readily cleanable. In every room and area in which any food is prepared, manufactured, processed, or prepackaged, or in which equipment or utensils are cleaned, sufficient natural or artificial lighting shall be provided to produce the following light intensity, while the area is in use:
(a) At least 10-foot candles for the following:
(1) At a distance of 30 inches above the floor, in walk-in refrigeration units, and dry food storage areas.
(2) At a working surface on which alcoholic beverages are prepared or where utensils used in the preparation or service of alcoholic beverages are cleaned.
(3) Inside equipment, such as reach-in or under-the-counter refrigerators.
(b) At least 20-foot candles for the following:
(1) At a surface where food is provided for consumer self-service or where fresh produce or prepackaged foods are sold or offered for consumption.
(2) In server stations where food is prepared.
(3) At a distance of 30 inches above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms.
(c) Except in server stations where food is prepared, at least 50-foot candles at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
Observed the lack of shatterproof light covers in the ware washing area. Light fixtures in area where food is prepared, open food is stored, or utensils are cleaned shall be of shatterproof construction or shall be protected with shatterproof shields and shall be readily cleanable. 0110 RETAIL MARKET<2000 SQ FT (HM3)
9-05-2018 The potable water supply shall be protected with a backflow or back siphonage protection device, as required by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, 114189.1, 114190, 114192.1, 114193, 114193.1, 114195, 114197, 114199, 114201, 114269) 2.00 All plumbing and plumbing fixtures shall be installed in compliance with local plumbing ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Observed lack of one inch minimum air gap between the drain lines under the janitorial sink and the rim height of the floor sink. Repair or modify drain lines so that the distance between the lowest edge of the drain lines and the height of the floor sink rim allows for a minimum of a one inch air gap. 0110 RETAIL MARKET<2000 SQ FT (HM3)
9-05-2018 All food employees shall have adequate knowledge of and be trained in food safety as it relates to their assigned duties. The person in charge shall have adequate knowledge of, and shall educate employees of the food facility regarding major food allergens. (113947) Food facilities that prepare, handle or serve non-prepackaged potentially hazardous food, shall have an employee who has passed an approved food safety certification examination. (113947-113947.1) 2.00 The responsibilities of the staff member certified in food safety include ensuring that all employees who handle, or have responsibility for handling, unpackaged foods of any kind have sufficient knowledge to ensure the safe preparation and /or service of the food. The nature and extent of the knowledge that each employee is required to have may be tailored, as appropriate, to the employee's duties related to food safety issues. Observed lack of proof that a current employee of this establishment holds a Food Safety Manager Class certificate that is no more than five years old. Maintain a copy of the original certificate for at least one current employee at the facility location. The food managers certificate that is earned by the employee or owner may be used at only one location. Obtain a certificate from an American National Standards Institute approved food handling/food safety examination; if no one holds a current food safety certificate, obtain one within 60 days.

(CDI) Observed the lack of knowledge of proper dish washing techniques. Proper dish washing techniques were explained during the inspection. Facility must use three compartments to properly wash dishes.

Observed towels and other material used to line the integrated drain boards at the three compartment sink. Remove and discontinue practice. Have clean/sanitized dishes air dried on the bare integrated drainboards.
0110 RETAIL MARKET<2000 SQ FT (HM3)
9-05-2018 Food shall be stored in an approved manner, in approved containers and labeled as to contents. Food shall be stored at least 6" above the floor on approved shelving. (114047, 114049, 114051, 114053, 114055, 114067(h), 114069) 2.00 Provide adequate and suitable space for the storage of food. Store food at least 6 inches off the floor. Store bulk food not stored in original packaging in containers identifying the food by common name. Food shall not be stored in locker rooms, restrooms, dressing rooms, refuse areas, or mechanical rooms; under open stairwells; under lines on which water has condensed; under leaking water lines, including leaking automatic fire sprinkler heads: or under sewer lines that are not shielded to intercept potential drips.

Only prepackaged nonpotentially hazardous food or uncut produce may be displayed or sold outdoors by a food facility if outdoor displays have overhead protection that extends over all food items, and if all food items from the outdoor display are stored inside the fully enclosed food facility at all times other than during business hours.

Products that are held by the permit holder for credit, redemption, or return to the distributor, such as damaged, spoiled, or recalled products, shall be segregated and held in designated areas that are separated from food, equipment, utensils, linens, and single-use articles. All returned or damaged food products and food products from which the label has been removed shall be separated and stored in a separate area and in a manner that shall prevent adulteration of other foods and shall not contribute to a vermin problem.



Observed drink items sitting directly on the floor inside the walk-in fridge unit. Store all food items/utensils at least six inches off the ground, if not in original unopened packed containers. 0110 RETAIL MARKET<2000 SQ FT (HM3)
9-05-2018 Handwashing signs shall be posted in each toilet room, directing attention to the need to thoroughly wash hands after using the restroom. (113953.5)

No smoking signs shall be posted in food preparation, food storage, and warewashing areas. (113978)

Consumers shall be notified that clean tableware is to be used when they return to self-service areas such as salad bars and buffets. (114075)

Any food facility constructed before January 1, 2004 without public toilet facilities shall prominently post a sign within the food facility in a public area stating that toilet facilities are not provided. (113725.1, 114276, 114381 (e))
2.00 Post permit in a conspicuous place (It is recommended that the permit be in customer view.). Post a notice advising patrons that a copy of the most recent routine inspection report is available for review by interested parties. Keep a copy of the most recent health inspection report at the facility for customer review purposes.

Post and maintain a legible and conspicuous sign in each toilet room directing attention to the need to thoroughly wash hands after using the toilet.

Post and maintain a legible "No Smoking" sign in food preparation, food storage, and utensil washing areas.

(CDI) Observed the Lack of the Previous inspection report at the facility. Provide a copy at all times. A Copy was left at the facility at the end of the inspection. 0110 RETAIL MARKET<2000 SQ FT (HM3)