11-04-2020 |
All food employees shall have adequate knowledge of and be trained in food safety as it relates to their assigned duties. The person in charge shall have adequate knowledge of, and shall educate employees of the food facility regarding major food allergens. (113947) Food facilities that prepare, handle or serve non-prepackaged potentially hazardous food, shall have an employee who has passed an approved food safety certification examination. (113947-113947.1)
| 3.00 |
The responsibilities of the staff member certified in food safety include ensuring that all employees who handle, or have responsibility for handling, unpackaged foods of any kind have sufficient knowledge to ensure the safe preparation and /or service of the food. The nature and extent of the knowledge that each employee is required to have may be tailored, as appropriate, to the employee's duties related to food safety issues.
|
Observed the lack of a current food handler card at the facility. Provide one within 30 days. Any staff that pours drinks must have a food handler card. Volunteers do not require one.
|
0123 BAR
|
11-04-2020 |
The walls / ceilings shall have durable, smooth, nonabsorbent, light-colored, and washable surfaces. All floor surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily cleanable. Approved base coving shall be provided in all areas, except customer service areas and where food is stored in original unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114065, 114067, 114069, 114175, 114143, 114257, 114259.2, 114266, 114268, 114268.1, 114271, 114272)
| 2.00 |
All food facilities shall be kept clean, fully operative, and in good repair. Floor surfaces in all areas in which food is prepared, packaged or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and in all restrooms and hand washing areas shall be smooth and of durable construction and made from non absorbent material that is easily cleanable.
Each permanent food facility shall be fully enclosed in a building consisting of permanent floors, walls, and an overhead structure that meets minimum standards. Food facilities that are not fully enclosed on all sides and that are in operation on January 1, 1985, shall not be required to meet the requirements of this section until the facility is remodeled or has a significant menu change or a change in its method of operation. Full enclosure is not required for dining areas and certain other areas when approved for outdoor food services.
|
(REPEAT VIOLATION 3rd time) Observed lack of coving along the base of the wall beneath the hand sink in the bar area. Provide approved cove base. Rubber top set will not be approved. Some approved coving would be one of two options. 1) Speedcove, or 2) Slimfoot sanitary cove ceramic tile (Dal-Tile).
NEW VIOLATION Observed a wood shelf behind the hand sink in the service area. Paint with a semi-gloss or high gloss paint.
|
0123 BAR
|
11-04-2020 |
Handwashing signs shall be posted in each toilet room, directing attention to the need to thoroughly wash hands after using the restroom. (113953.5)
No smoking signs shall be posted in food preparation, food storage, and warewashing areas. (113978)
Consumers shall be notified that clean tableware is to be used when they return to self-service areas such as salad bars and buffets. (114075)
Any food facility constructed before January 1, 2004 without public toilet facilities shall prominently post a sign within the food facility in a public area stating that toilet facilities are not provided. (113725.1, 114276, 114381 (e))
| 1.00 |
Post permit in a conspicuous place (It is recommended that the permit be in customer view.). Post a notice advising patrons that a copy of the most recent routine inspection report is available for review by interested parties. Keep a copy of the most recent health inspection report at the facility for customer review purposes.
Post and maintain a legible and conspicuous sign in each toilet room directing attention to the need to thoroughly wash hands after using the toilet.
Post and maintain a legible "No Smoking" sign in food preparation, food storage, and utensil washing areas.
|
Observed lack of a visibly posted notice to inform patrons that the facility is inspected by the local health department. Maintain a sign in a conspicuous location to inform patrons that the facility is inspected. (A copy of the required notice is available on the Merced County Environmental Health website).
|
0123 BAR
|
11-04-2020 |
Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons: in establishments with more than 20,000 sq ft.; establishments offering on-site food consumption. (113953, 113953.1, 113953.2, 114250, 114250.1, 114276)
| 1.00 |
Provide clean toilet facilities in good repair. Provide permanently installed toilet tissue dispenser(s) in all toilet facilities. Provide handwashing facilities within or adjacent to all toilet facilities. Soap shall be provided in dispensers at, or adjacent to, handwashing facilities. Single-use sanitary towels in dispensers or hot-air blowers shall be provided at handwashing facilities.
Customer restrooms are required for food facilities of more than 20,000 square feet if they were constructed after July 1 1984, and also applies to facilities of any size that were constructed after January 1, 2004 where there is onsite consumption of food. A "take-out only" food facility, with no seating indoors or outdoors, may not be required to provide customer restrooms. Check with the Division of Environmental Health and with the appropriate Planning Department before removing or restricting access to customer restrooms.
|
Observed the men's restroom fan appears to be broken. Toilet rooms shall be vented to the outside air by means of an openable, screened window, an air shaft, or a light-switch-activated exhaust fan, consistent with the requirements of local building codes.
|
0123 BAR
|