Return To Restaurant Listing | Return to Environmental Health Homepage

Facility: Anberry Health Care - NPN
Address: 1685 Shaffer Rd, Atwater, CA

The most recent inspection of this food facility resulted in a rating of
Good (Total Points: 1.00)
0-6  Points: Good
7-13 Points: Satisfactory
14+  Points: Unsatisfactory
Rating on date 10-15-2024: Good (Total Points: 1.00)
DateViolationPointsCorrectionInspector CommentsFacility Area
10-15-2024 Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors, and smoke and be approved by the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) 1.00 All areas shall have sufficient ventilation to facilitate proper food storage and to provide a reasonable condition of comfort for each employee, consistent with the job performed by the employee.

Light fixtures in areas where food is prepared, open food is stored, or utensils are cleaned shall be of shatterproof construction or shall be protected with shatterproof shields and shall be readily cleanable. In every room and area in which any food is prepared, manufactured, processed, or prepackaged, or in which equipment or utensils are cleaned, sufficient natural or artificial lighting shall be provided to produce the following light intensity, while the area is in use:
(a) At least 10-foot candles for the following:
(1) At a distance of 30 inches above the floor, in walk-in refrigeration units, and dry food storage areas.
(2) At a working surface on which alcoholic beverages are prepared or where utensils used in the preparation or service of alcoholic beverages are cleaned.
(3) Inside equipment, such as reach-in or under-the-counter refrigerators.
(b) At least 20-foot candles for the following:
(1) At a surface where food is provided for consumer self-service or where fresh produce or prepackaged foods are sold or offered for consumption.
(2) In server stations where food is prepared.
(3) At a distance of 30 inches above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms.
(c) Except in server stations where food is prepared, at least 50-foot candles at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
Observed the light fixture over the hood does not function, bulb may be burned out. Replace bulb and / or repair fixture. Failure to provide adequate lighting. 0104 LICENSED HEALTH CARE FAC. (16-99 BEDS)


Rating on date 2-02-2021: Good (Total Points: 1.00)
DateViolationPointsCorrectionInspector CommentsFacility Area
2-02-2021 All utensils and equipment shall be fully operative, clean, and in good repair. (114115, 114175). All utensils and equipment shall be approved, installed properly, and meet applicable standards. (114130, 114130.1, 114130.2, 114130.3, 114130.4, 114130.5, 114130.6, 114132, 114133, 114137, 114139, 114143, 114153, 114155, 114163, 114165, 114167, 114169, 114172, 114175, 114177, 114180, 114182) 1.00 Equipment food-contact surfaces and utensils shall be clean to sight and touch. The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other debris accumulations.

Keep all food facilities, and all utensils, display cases, windows, counters, shelves, tables, refrigeration units, sinks, dishwashing machines, and other equipment or utensils used in the storage, preparation, sale, service, and display of food, clean, fully operative, and in good repair.

The non-food-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris. Equipment shall be reassembled so that food-contact surfaces are not contaminated.
Observed the left door of the upright two door Atosa Refrigerator is broken. Repair/replace so it is in working condition. Work order has already been placed. This did not affect the temperature inside the unit.

Observed the walk-in freezer door may need a replacement door seal. This may be causing condensation/ice build up inside the freezer. Repair/replace so there is a proper seal to prevent ice build up inside the unit.